Nevada Active Corporation (Inc. Nov 5, 2021) | Entity: E18766142021-9 · NVID: NV20212273605 · EIN: 87-3634087
S1: 2026SR1024392 S2: 2026SR1030308 Phase A Linux Web Re-Host

Fleet Guardian™ Control Plane — Interactive Telemetry, 4-Tuple Conflict Detection & Approval-Gated Self-Healing

Direct browser re-host of the five functional modules specified in the 20-page software specification filed with S2: System Monitoring, On-Demand Diagnosis, Approval-Gated Self-Healing, Intelligent Resource Scheduling, and Log Audit.

Cluster Group Tree
Network Traffic Share
Inbound + Outbound MB by Cluster Group
Avg CPU Utilisation
57.4%
Threshold: Warn 80% / Crit 90%
Avg Memory Utilisation
64.2%
ECC & Sub-NUMA Monitored
Avg Disk Utilisation
51.7%
SMART & RAID Cache Guard
Total Network Traffic
9,212 MB
Scope: All Fleet Nodes
Live Physical Node Telemetry & 4-Tuple Firmware Matrix (10-Column S2 Schema)
Auto-refresh every 3.0s
Node ID IP & Hostname Vendor / Gen BMC / BIOS Status CPU % Mem % Disk % In / Out (MB) Procs
ODG-API-01
10.24.33.151
us-or-api-turin-01.odg.internal
Lenovo EPYC-Turin
XCC2 4.10
BIOS D8E134A
NORMAL 44.2% 46.8% 31.5% 412.5 / 428.9 175
ODG-API-02
10.24.33.152
us-or-api-h3c-02.odg.internal
H3C Gen11
HDM 3.12
BIOS 6.00.21
WARNING 81.5% 64.0% 42.8% 518.4 / 509.2 292
ODG-API-03
10.24.33.153
us-or-api-kks-03.odg.internal
KuaiKuaiSuan Gen11
AST2600 1.14
BIOS 2.10
NORMAL 39.4% 43.1% 29.0% 286.0 / 291.5 160
ODG-DB-01
10.24.22.201
us-tx-db-hygon-01.odg.internal
H3C Hygon-C86
HDM 2.56
BIOS 2.00.48
NORMAL 64.1% 79.2% 61.5% 312.0 / 298.4 276
ODG-DB-02
10.24.22.202
us-tx-db-icx-02.odg.internal
Inspur Gen11
iBMC 6.12
BIOS 5.0.14
SEVERE 92.8% 88.4% 87.2% 542.6 / 488.1 334
ODG-DB-03
10.24.22.203
us-tx-db-dell-03.odg.internal
Dell Gen10
iDRAC9 6.10.80
BIOS 2.21.2
NORMAL 55.4% 72.1% 58.0% 268.4 / 249.0 230
ODG-DB-04
10.24.22.204
us-or-db-xfu-04.odg.internal
xFusion Gen11
iBMC 3.18
BIOS 1.42
NORMAL 47.9% 68.3% 49.4% 215.7 / 204.2 198
ODG-GPU-01
10.24.44.211
us-va-gpu-a100-01.odg.internal
Inspur Gen11
iBMC 6.22
BIOS 5.1.08
NORMAL 68.4% 74.5% 53.2% 460.2 / 445.0 284
ODG-GPU-02
10.24.44.212
us-va-gpu-g10-02.odg.internal
Dell Gen10
iDRAC9 6.10.80
BIOS 2.19.1
NORMAL 59.1% 66.8% 48.7% 378.0 / 362.4 240
ODG-WEB-01
10.24.11.101
us-va-web-g9-01.odg.internal
HPE Gen9
iLO4 2.81
BIOS P89 v2.92
NORMAL 42.4% 58.1% 41.0% 184.2 / 210.5 164
ODG-WEB-02
10.24.11.102
us-va-web-g10-02.odg.internal
HPE Gen10
iLO5 2.96
BIOS U30 v2.78
NORMAL 51.2% 62.4% 44.5% 226.8 / 254.1 188
ODG-WEB-03
10.24.11.103
us-va-web-g11-03.odg.internal
Dell Gen11
iDRAC9 7.10.30
BIOS 1.18.2
WARNING 78.6% 71.0% 86.4% 340.5 / 389.0 245
ODG-WEB-04
10.24.11.104
us-va-web-kp950-04.odg.internal
Huawei Kunpeng-950
iBMC 5.68
BIOS 1.86
NORMAL 49.0% 54.2% 38.2% 295.4 / 318.7 212
ODG-WEB-05
10.24.11.105
us-tx-web-ins-05.odg.internal
Inspur Gen10
iBMC 4.29
BIOS 4.1.30
NORMAL 38.7% 49.5% 52.1% 142.0 / 165.3 148
PAPERS J3 & J4 · FOUR-PART COMPOSITE KEY

Interactive BIOS/BMC Compatibility Conflict Detector

Redfish UpdateService
KB-FG-001 · Inspur (Gen10)
ENFORCE_BMC_FIRST Out-of-Band Interruption
4-Tuple Key: Gen10 | NF5280M5 YZMB-00882 | iBMC < 4.22 | BIOS >= 4.1.20

Applying BIOS 4.1.20–4.1.30 over iBMC below 4.22 invalidates the SMBIOS Type 42 management controller host interface table, dropping Redfish/IPMI sessions and dark-screening remote KVM.

Remedy: Split change order into two maintenance stages: Stage 1 upgrades iBMC to >= 4.29 with atomic BMC cold reset; Stage 2 flashes BIOS 4.1.30 via Redfish UpdateService ApplyTime=OnReset.
KB-FG-002 · HPE (Gen9)
BLOCK_BATCH Rollback Unavailability
4-Tuple Key: Gen9 | ProLiant DL380 Gen9 v2.1 | iLO4 < 2.78 | P89 >= v2.90

Across 5,758 production iLO4 nodes, flashing P89 v2.90+ over iLO4 < 2.78 corrupts the redundant ROM backup bank pointer, rendering dual-image automatic rollback unavailable on cold-boot failure.

Remedy: Block batch execution. Enforce iLO4 upgrade to 2.81 and verify backup ROM bank checksum via Redfish OEM probe before unlocking BIOS capsule dispatch.
KB-FG-003 · Dell (Gen11)
SPLIT_WAVE Sensor Consistency Offset
4-Tuple Key: Gen11 | PowerEdge R760 rev.A04 | iDRAC9 7.00.xx | BIOS 1.18.x

In mixed Gen10/Gen11 racks, iDRAC9 7.00.xx paired with BIOS 1.18.x introduces a +1.9°C inlet/exhaust sensor conformity offset, triggering premature fan-curve saturation and thermal throttling.

Remedy: Upgrade iDRAC9 to 7.10.30+ prior to BIOS 1.18.2; run post-flash sensor conformity check (MAE threshold <= 0.8°C) before releasing canary lock.
KB-FG-004 · Huawei (Kunpeng-950)
ENFORCE_BMC_FIRST Boot Chain Instability
4-Tuple Key: Kunpeng-950 | TaiShan 2280 V2 BC82AMDDA | iBMC < 5.60 | BIOS >= 1.82

UEFI ARM64 ACPI power-capping table handshake deadlocks during cold boot when BIOS >= 1.82 boots against iBMC < 5.60, leaving SP686 RAID controller unenumerated.

Remedy: Require iBMC >= 5.68 and verify Ctrip-AlmaLinux 9.x SP686 RAID RPM signature & UEFI SecureBoot dbx measurement prior to rolling wave.
KB-FG-005 · H3C (Gen11)
BLOCK_BATCH Sensor Consistency Offset
4-Tuple Key: Gen11 | UniServer R4900 G6 RE-AE52 | HDM 3.08 | BIOS 6.00.1x

5th-Gen Intel 4510 ROR configuration exhibits ~50% higher tail latency and 20% memory bandwidth shortfall on CXMT DIMMs when BIOS sub-NUMA clustering & memory training policy are left at factory defaults.

Remedy: Hold node in BIOS tuning state; apply validated memory training profile and run single-chassis STREAM/lmbench verification before production pooling.
KB-FG-006 · H3C (Hygon-C86)
SPLIT_WAVE Boot Chain Instability
4-Tuple Key: Hygon-C86 | UniServer R4950 G5 | HDM >= 2.50 | BIOS 2.00.48

Hygon C86 5480 platform requires explicit operator library alignment and IOMMU passthrough flags after BIOS 2.00.48 update to maintain <3% TPC-H runtime parity against Ice Lake 4309Y.

Remedy: Run post-boot operator library verification probe and canary TPC-H micro-benchmark before advancing partitioned rolling wave.
KB-FG-007 · Lenovo (EPYC-Turin)
ENFORCE_BMC_FIRST Out-of-Band Interruption
4-Tuple Key: EPYC-Turin | ThinkSystem SR665 V3 RE-AE51 | XCC2 < 4.05 | BIOS D8E134A

Redfish UpdateService MultipartHttpPush URI returns HTTP 400 or stalls virtual media mount when pushing Turin AGESA capsule over XCC2 < 4.05.

Remedy: Upgrade XCC2 to 4.10 first, validate Redfish UpdateService PushUri probe, and enforce concurrency cap = 1 per fault domain.
KB-FG-008 · xFusion (Gen11)
SPLIT_WAVE Rollback Unavailability
4-Tuple Key: Gen11 | FusionServer 2288H V7 | iBMC 3.12 | BIOS 1.40+

JBOD mode assignment on replacement drives fails silently after RAID controller firmware reset hang if BMC storage inventory cache is not flushed post-flash.

Remedy: Insert mandatory out-of-band storage controller cache flush and storcli JBOD verification probe into post-upgrade health check chain.
S1 & S2 · HUMAN-IN-THE-LOOP REMEDIATION

Approval-Gated Self-Healing & Fail-Stop Audit Log

HEAL-20261123-002 · ODG-WEB-03 (10.24.11.103) SUCCESS (425 ms)
Fault: Disk Utilization (86.4%) & Gen10/Gen11 Sensor Drift Warning
Policy: POL-WEB-STORAGE-02 (Auto-Clean + Approved Rebalance) | Gate: Approved by Change Lead (Audit Logged)
Step 1: Clear Temporary Diagnostic Spool SUCCESS (88ms)
Step 2: Verify Redfish OOB Session & Sensor MAE <= 0.8°C SUCCESS (195ms)
Step 3: Re-weight Load Balancer Pool (Weighted Round Robin) [Requires Signature] APPROVED_AND_EXECUTED (142ms)
HEAL-20261123-001 · ODG-DB-02 (10.24.22.202) PAUSED AT APPROVAL GATE
Fault: CPU (92.8%) & Memory (88.4%) Exceeded Severe Threshold
Policy: POL-DB-HIGHLOAD-01 (5-Step Bounded Remediation) | Gate: Intercepted — Awaiting Operator Signature
Step 1: Clear Logs (/var/log/journal vacuum) SUCCESS (112ms)
Step 2: Release PageCache & Slab Buffer SUCCESS (164ms)
Step 3: Migrate Load (Drain Active Connections) [Requires Signature] INTERCEPTED_AWAITING_APPROVAL (0ms)