Fleet Guardian™ Control Plane — Interactive Telemetry, 4-Tuple Conflict Detection & Approval-Gated Self-Healing
Direct browser re-host of the five functional modules specified in the 20-page software specification filed with S2: System Monitoring, On-Demand Diagnosis, Approval-Gated Self-Healing, Intelligent Resource Scheduling, and Log Audit.
| Node ID | IP & Hostname | Vendor / Gen | BMC / BIOS | Status | CPU % | Mem % | Disk % | In / Out (MB) | Procs |
|---|---|---|---|---|---|---|---|---|---|
| ODG-API-01 |
10.24.33.151
us-or-api-turin-01.odg.internal
|
Lenovo EPYC-Turin |
XCC2 4.10
BIOS D8E134A
|
NORMAL | 44.2% | 46.8% | 31.5% | 412.5 / 428.9 | 175 |
| ODG-API-02 |
10.24.33.152
us-or-api-h3c-02.odg.internal
|
H3C Gen11 |
HDM 3.12
BIOS 6.00.21
|
WARNING | 81.5% | 64.0% | 42.8% | 518.4 / 509.2 | 292 |
| ODG-API-03 |
10.24.33.153
us-or-api-kks-03.odg.internal
|
KuaiKuaiSuan Gen11 |
AST2600 1.14
BIOS 2.10
|
NORMAL | 39.4% | 43.1% | 29.0% | 286.0 / 291.5 | 160 |
| ODG-DB-01 |
10.24.22.201
us-tx-db-hygon-01.odg.internal
|
H3C Hygon-C86 |
HDM 2.56
BIOS 2.00.48
|
NORMAL | 64.1% | 79.2% | 61.5% | 312.0 / 298.4 | 276 |
| ODG-DB-02 |
10.24.22.202
us-tx-db-icx-02.odg.internal
|
Inspur Gen11 |
iBMC 6.12
BIOS 5.0.14
|
SEVERE | 92.8% | 88.4% | 87.2% | 542.6 / 488.1 | 334 |
| ODG-DB-03 |
10.24.22.203
us-tx-db-dell-03.odg.internal
|
Dell Gen10 |
iDRAC9 6.10.80
BIOS 2.21.2
|
NORMAL | 55.4% | 72.1% | 58.0% | 268.4 / 249.0 | 230 |
| ODG-DB-04 |
10.24.22.204
us-or-db-xfu-04.odg.internal
|
xFusion Gen11 |
iBMC 3.18
BIOS 1.42
|
NORMAL | 47.9% | 68.3% | 49.4% | 215.7 / 204.2 | 198 |
| ODG-GPU-01 |
10.24.44.211
us-va-gpu-a100-01.odg.internal
|
Inspur Gen11 |
iBMC 6.22
BIOS 5.1.08
|
NORMAL | 68.4% | 74.5% | 53.2% | 460.2 / 445.0 | 284 |
| ODG-GPU-02 |
10.24.44.212
us-va-gpu-g10-02.odg.internal
|
Dell Gen10 |
iDRAC9 6.10.80
BIOS 2.19.1
|
NORMAL | 59.1% | 66.8% | 48.7% | 378.0 / 362.4 | 240 |
| ODG-WEB-01 |
10.24.11.101
us-va-web-g9-01.odg.internal
|
HPE Gen9 |
iLO4 2.81
BIOS P89 v2.92
|
NORMAL | 42.4% | 58.1% | 41.0% | 184.2 / 210.5 | 164 |
| ODG-WEB-02 |
10.24.11.102
us-va-web-g10-02.odg.internal
|
HPE Gen10 |
iLO5 2.96
BIOS U30 v2.78
|
NORMAL | 51.2% | 62.4% | 44.5% | 226.8 / 254.1 | 188 |
| ODG-WEB-03 |
10.24.11.103
us-va-web-g11-03.odg.internal
|
Dell Gen11 |
iDRAC9 7.10.30
BIOS 1.18.2
|
WARNING | 78.6% | 71.0% | 86.4% | 340.5 / 389.0 | 245 |
| ODG-WEB-04 |
10.24.11.104
us-va-web-kp950-04.odg.internal
|
Huawei Kunpeng-950 |
iBMC 5.68
BIOS 1.86
|
NORMAL | 49.0% | 54.2% | 38.2% | 295.4 / 318.7 | 212 |
| ODG-WEB-05 |
10.24.11.105
us-tx-web-ins-05.odg.internal
|
Inspur Gen10 |
iBMC 4.29
BIOS 4.1.30
|
NORMAL | 38.7% | 49.5% | 52.1% | 142.0 / 165.3 | 148 |
Interactive BIOS/BMC Compatibility Conflict Detector
Applying BIOS 4.1.20–4.1.30 over iBMC below 4.22 invalidates the SMBIOS Type 42 management controller host interface table, dropping Redfish/IPMI sessions and dark-screening remote KVM.
Across 5,758 production iLO4 nodes, flashing P89 v2.90+ over iLO4 < 2.78 corrupts the redundant ROM backup bank pointer, rendering dual-image automatic rollback unavailable on cold-boot failure.
In mixed Gen10/Gen11 racks, iDRAC9 7.00.xx paired with BIOS 1.18.x introduces a +1.9°C inlet/exhaust sensor conformity offset, triggering premature fan-curve saturation and thermal throttling.
UEFI ARM64 ACPI power-capping table handshake deadlocks during cold boot when BIOS >= 1.82 boots against iBMC < 5.60, leaving SP686 RAID controller unenumerated.
5th-Gen Intel 4510 ROR configuration exhibits ~50% higher tail latency and 20% memory bandwidth shortfall on CXMT DIMMs when BIOS sub-NUMA clustering & memory training policy are left at factory defaults.
Hygon C86 5480 platform requires explicit operator library alignment and IOMMU passthrough flags after BIOS 2.00.48 update to maintain <3% TPC-H runtime parity against Ice Lake 4309Y.
Redfish UpdateService MultipartHttpPush URI returns HTTP 400 or stalls virtual media mount when pushing Turin AGESA capsule over XCC2 < 4.05.
JBOD mode assignment on replacement drives fails silently after RAID controller firmware reset hang if BMC storage inventory cache is not flushed post-flash.